◆ Overview of basic facilities in exhibition hall
 
● Exhibition venue

Clearance heights: 8-17m (D1-D3: 10m; D4-D15: 9m; B1 and B2: 8m; Zone E: 17m).
 
Ground bearing capacity of exhibition hall: 0.15-3.5t/m ² (The floor bearing capacity of the Certificate Processing Hall is 0.15 t/m²; of Osmanthus Hall 0.5 t/m²; of the exhibition halls D1, D3, D4, D5, D14, D15, Chinese Hibiscus Hall 1.5 t/m² respectively; of the exhibition halls D2, D6, D13, B1 and Zone E 3.5 t/m² respectively; of the exhibition hall B2 2.5 t/m²)。
 
 
● Elevators
 
There are 85 elevators in total, including 40 escalators (22 indoor and 18 outdoor), 32 vertical passenger elevators and 10 freight elevators.
 
 
● Booth power
 
Booth box capacity configuration:
 
The capacity of each outlet box in the exhibition halls D1-D6 and D13-D15 is 30KW/3P, which can supply 15KW/AC380V and 3KW/AC220V international exhibition standard mode power interfaces;
 
The capacity of each outlet box in the exhibition halls D7-D12 is 50KW/3P, which can supply 30KW/AC380V, 15KW/AC380V, 3KW/AC220V international exhibition standard mode power interface;
 
The capacity of each outlet box in the exhibition halls B1, B2 and Zone E is 50KW/3P, which can supply 30KW/AC380V, 15KW/AC380V and 3KW/AC220V international exhibition standard mode power interfaces.
 
 
● Brightness of exhibition halls
 
The normal lighting and emergency lighting are distributed at intervals with brightness at 300lx~400lx (Lux).
 
 
● Water supply and drainage
 
The exhibition halls D1-D3, D7-D12, B1, B2 and Zone E are equipped with water supply and drainage functions.
 
 
● Fire fighting
 
Equipped with fire alarm system, smoke control system, fire hydrant system, automatic fire monitor system and portable fire extinguishers
 
 
● Air conditioner
 
The total installed capacity of air conditioners is 14,800RT, with the cooling load of the exhibition hall reaching 368KW/㎡.
 
 
● Air supply
 
 The exhibition halls B1, B2 and Zone E can provide compressed air. The air supply point is located in the outlet box of the booth. The air supply pressure of each fast interface of air supply is 0.8Mpa.
 
 
● Broadcasting system
 
 Covering the whole area of exhibition halls
 
 
● Emergency lighting
 
 Covering the whole area of exhibition halls
 
 
● Telecommunication network systems
 
The Internet system is accessed through China Telecom and China Mobile, which provide the 100M and 500M Internet network service respectively.
 
The communication system is provided by China Telecom and China Mobile respectively, with China Telecom providing 500 domestic/international voice calls and China Mobile providing 200 domestic/international voice calls.